Einrichtungsanleitung
Axis Network cameras (RTSP/ONVIF)
Local RTSP/ONVIF stream (S/G/T). Path /axis-media/media.amp, port 554; resolution/profile via query params (?resolution=, ?streamprofile=), no numbered sub-path. Swedish manufacturer (NDAA-compliant).
Inbetriebnahme
So richten Sie sie ein
Bevor Sie beginnen
- RTSP enabled in the camera's web interface (System > Network > RTSP) — on by default on most recent models, but worth checking.
- A dedicated user account created on the camera (avoid using the default administrator account for a permanent stream).
- The camera's local IP address, ideally reserved on the router — or AXIS IP Utility / mDNS to find it.
- The model number (M/P/Q + series) in case of model-specific stream options (multi-sensor, fisheye).
Schritte
- In Noviscan's Sources screen, search for "Axis": the path /axis-media/media.amp and port 554 are pre-filled.
- Enter the IP, username and password of the camera account.
- For a specific resolution or stream profile, add the ?resolution=... or ?streamprofile=... parameters (VAPIX) to the path if the default does not suit.
- Leave the transport on TCP.
- Save: the source tests the connection.
Bei Problemen
- Connection refused: RTSP may be disabled in network settings — check System > Network > RTSP in the web interface.
- 400 error when adding a stream parameter: avoid combining videozprofile=storage with the adjustable live stream parameters (adjustablelivestream), known to conflict.
- Multi-sensor/multi-lens model: add ?camera=1,2… to the path to pick the sensor.
- Authentication refused: create a dedicated account in the camera interface rather than using the default administrator account.
Quellen geprüft am 2026-08-01.
Nachvollziehbarkeit
Woher diese Informationen stammen
Jede Angabe auf dieser Seite stützt sich auf eine datierte und überprüfbare Quelle. Eine Herstelleranleitung kann sich ändern: Das Abrufdatum sagt Ihnen, wie aktuell die Information ist.
- https://developer.axis.com/vapix/network-video/rtsp-adjustable-live-stream/ — officiel (VAPIX, chemin RTSP, re-vérifié) (2026-08-01)
- https://www.ispyconnect.com/camera/axis — communautaire (modèles) (2026-07-22)
Praxistest
Noviscan auf dem Prüfstand
Surveilbench veröffentlicht Tests von Videoüberwachungssoftware, mit offengelegter Methodik. Surveilbench wird von Secufor herausgegeben, dem Anbieter von Noviscan.